DRE Waveline Pro

Ask About Financing

Available in US only.

Need Equipment Advice?

Ask Our Experts! (800) 462-8195

Details

Superior flexibility and performance with a premium flat panel display is found in DRE's newest version of the Waveline monitor series. The DRE Waveline Pro can be used on small, medium, or large animals. An applicable monitor for veterinary surgical suites and research facilities — Now with Masimo SET® Pulse Oximetry!

The DRE Waveline Pro displays as many as eight colorful waveforms on a crisp 15” high resolution display. It is lightweight, portable and measures multiple parameters, including ECG (3 or 5 lead) with ST segment monitoring, resp., dual temp., Masimo SpO2 and NIBP. Configurations are available that measure capnography, dual channel IBP, and anesthetic agents (five agents, Auto ID, N2O, FiO2 and Sidestream EtCO2), and that have a built-in thermal printer.

Multiple Configurations Available:

  • Standard Parameters: ECG, Masimo Pulse Oximetry, 2 x Temperature, NIBP, Respiration, and Printer
  • Optional Parameters: Invasive Blood Pressures, CO2 (Mainstream or Sidestream) and Drager Built-in Anesthetic Agent Module
  • Comes with standard veterinary accessories

Features:

  • EtCO2 (mainstream or sidestream) (Respironics)
  • Multi-lead simultaneous ECG monitoring
  • Automatically set alarm limits
  • New for 2015! Masimo SET® Pulse Oximetry — ask your DRE representative for details
  • Graphical and tabular trending
  • Color-coded alarms
  • Patient data entry
  • Battery backup (two removable batteries)
  • Built-in thermal recorder
  • Networking capability
  • Large (15”), high resolution flat panel display
  • Available with a built-in thermal printer

Specifications

Physical Dimensions & Weight:

  • Base Unit: 12.1”/309 mm (H) x 14.4”/365 mm (W) x 6.3”/159 mm (D)
  • Weight: 17.6 lbs/8.0 kgs (including anesthetic agents module and batteries)

Application:

  • Small, Medium, and Large animal

Performance Specifications:

  • Display: 15” color TFT, Resolution 1024 x 768
  • Trace: 8 waveforms
  • Indicators:
    • Alarm indicator
    • Power indicator
    • QRS beep and alarm sound
  • Trend time: 1 – 48 hours
  • Recorder:
    • Built-in, thermal array, 2 channels
    • Record width: 1.9”/48 mm
    • Recorder paper: 2”/50 mm
    • Record speed: 25 mm/s, 50 mm/s

ECG:

  • Input: 5-lead ECG cable and standard AAMI line for connection
  • Lead Choice: I, II, III, aVR, aVF, aVL, V, TEST
  • Gain Choice : x0.5, x1, x2, x4
  • Frequency Characteristic: 0.05 ~ 35 HZ (+3dB)
  • ECG Waveforms: 7 channels
  • Penetration Voltage: 4000VAC 50/60Hz
  • Sweep Speed: 12.5, 25 and 50 mm/s
  • HR Display Range: 30 – 300bpm
  • Accuracy: 1 bpm or 1%, whichever is greater
  • Alarm Limit Range Setting: Upper limit 100 – 200 bpm; Lower limit 30 – 100 bpm

RESP:

  • Measure Method: RA-LL impedance
  • Range: 0 – 120 rpm
  • Accuracy: 3 rpm
  • Alarm Limit Setting: Upper limit 6 – 120 rpm: Lower limit 3 – 120 rpm
  • Sweep Speed: 12.5 and 25 mm/s

TEMP:

  • Range: 25 – 50 (C)
  • Accuracy:
    • 0.2 C (25.0 – 34.9 C)
    • 0.1 C (35.0 – 39.9 C)
    • 0.2 C (40.0 – 44.9 C)
    • 0.3 C (45.0 – 50.0 C)
  • Display Resolution: 0.1 C
  • Alarm Limit Setting: Upper limit 0 – 50 C, lower limit 0 – 50 C
  • Channel: 2 channels

Masimo SET SpO2

  • Measuring Range:
    • SpO2: 1~100 %
    • PR: 25~20 %
  • SpO2 Accuracy (non-motion):
    • Adult Pediatric: 70~69%: unspecified
    • Neonate: 70~69 %: unspecified
  • SpO2 Accuracy (motion):
    • Adult Pediatric: 70~100 %: ±3 %, 0~100 %: ± 3 %, 0~240 bpm: ±3 bpm
  • PR Accuracy (motion):
    • Adult Pediatric Neonate: 25<span 20.8px;"="">~240 bpm: ±5 bpm
  • Low Perfusion Performance: >0.02 % Pulse Amplitude and % Transmission >5
    • SpO2: ±2 %
    • PR: ±3 bpm
  • Modes:
    • Averaging mode: 2,4,8,10,12,14 and 16 s
    • Sensitivity: Normal, APOD and Maximum

NIBP:

  • Measuring Technology: Automatic oscillating measurement
  • Cuff Inflating: <30s (0 – 300 mmHg, standard adult cuff)
  • Measuring Period: AVE<40s
  • Mode: Manual, Auto
  • Measuring Interval in AUTO Mode: 2 min – 4 hrs
  • Pulse Rate Range: 30 – 250 (bpm)
  • Measuring Range:
    • Adult/Pediatric Mode: SYS: 40 – 250 (mmHg) DIA :15 – 200 (mmHg)
    • Neonatal Mode: SYS: 40 – 135 (mmHg) DIA : 15 – 100 (mmHg)
  • Resolution: 1mmHg

Accuracy:

  • Maximum Mean error: 5mmHg
  • Maximum Standard deviation: 8mmHg
  • Overpressure Protection:
    • Adult Mode: 300(mmHg)
    • Neonatal Mode: 160 (mmHg)
  • Alarm Limit Setting:
    • SYS: 50 – 240 mmHg
    • DIA: 15 – 180 mmHg

IBP:

  • Measurement Range: -50 – 300mmHg
  • Channel: 2 channels
  • Pressure Transducer: Sensitivity, 5μV/V/mmHg
  • Impedance Range: 300 – 3000Ω
  • Transducer Sites: ART, PA,CVP, RAP, LAP, ICP
  • Unit: mmHg/kPa selectable
  • Resolution: 1 mmHg
  • Accuracy: 1 mmHg or 2%, whichever is greater
  • Alarm Range: -10 – 300 mmHg

EtCO2 (Respironics) (mainstream or sidestream):

  • CO2 Measurement Range: 0 – 99 mmHg

Accuracy:

  • 2 mmHg (0 – 38 mmHg)
  • 39-99 mmHg 5% of reading + 0.08% for every 1 mmHg (above 38 mmHg)
  • Sampling Rate: 50 ml/min
  • Initialization Time: 30 seconds (typical), reaches 5% steady-state accuracy within 3 minutes
  • Respiration Rate: 0 – 150 breaths/min
  • Mode: Adult, neonate

Anesthetic Agents:

  • Industry standard 802.11b/g wireless network

Power:

  • Source: External AC power or internal battery
  • AC Power: 100 – 240VAC, 50/60Hz, 150VA
  • Battery: Built-in and rechargeable
  • Charge Time: 4 hours

Environmental Specifications:

  • Operating Temperature: 5 – 40 C
  • Storage Temperature: -20 – 65 C
  • Operating Humidity: ≤80 %