DRE Waveline EZ

Ask About Financing

Available in US only.

Need Equipment Advice?

Ask Our Experts! (800) 462-8195

Details

Portable patient monitor with a user-friendly touch-screen — Now with Masimo SET® Pulse Oximetry!

ECG, Respiration, Masimo SpO2, Noninvasive Blood Pressure and Temperature. Available with a printer.

Featuring cutting-edge innovations and impeccable craftsmanship, the DRE Waveline EZ patient monitor is the perfect choice for healthcare professionals who demand precision, performance and affordability. It features an intuitive touchscreen that helps you quickly and accurately evaluate patient conditions, resulting in better patient care. Utilize the Waveline EZ to monitor ECG, respiration, SpO2, NIBP and temperature; it’s also available with EtCO2 monitoring and a printer.

Features:

  • Touch-screen provides immediate operation
  • Simultaneous multi-lead ECG monitoring
  • New for 2015! Masimo SET® Pulse Oximetry — ask your DRE representative for details
  • Advanced ST and arrhythmia detection
  • Graphical and tabular trending
  • Displays three waveforms
  • Battery backup
  • Audible and visual alarms
  • Quick BP readings recall

Specifications

Physical Dimensions:

  • Size:6 lbs
  • Dimensions:10x8x4 (wxhxd)

Safety Approval & Quality System:

  • Designed to meet IEC60601-1-1988, EN60601-1-1, EN60601-2
  • Class II Equipment, double insulated
  • Type BF applied parts
  • ISO9001 & EN46001 Certified

Power Requirements:

  • Power Supply: AC 90-264V/47-63Hz
  • Input Power: ≤55VA
  • Fuses: Two fuse sockets in the rear panel indicated by “FUSE”, OI 5X20, 2A/250V
  • Battery: 12V/4.0AH sealed lead-acid
  • Charge time: ≥4 hours
  • Operating time: ≥2 hours (full recharge)
  • Battery Charging Method: Automatic charging after monitor is connected to AC power supply (with charge protection function)
  • Discharge Protection: When powered by battery, the monitor will be automatically turned off when battery power is almost used up

ECG:

  • Patient Safety Standard: IEC60601-1-1988
  • CMRR ≥60dB (Common Mode Rejection Ratio)
  • Heart Rate Range: 20 ~ 254bpm 1bpm
  • Heart Rate Averaging: 8 second average
  • ST Segment Range: -0.8 ~ + 0.8mV
  • Interface: AAMI 6-pin
  • Lead Selection: I, II, III (3 lead mode)
  • I, II, III, aVR, aVL, aVF, V (5 lead mode) (ST and Arrhythmia analysis)
  • Lead Fault Alarm: Audible, Visual Input 5-lead ECG patient cable
  • QRS Indicator: Audible and Visual Alert
  • Waveform Storage: 6 minutes
  • Sweep Speed: 12.5/25/50 mm/sec
  • Gain Selection:4mV, 2mV, 1mV, 0.5mV, 0.25mV,Auto
  • Trends: 2 hours -> 4 hours -> 8 hours -> 24 hours -> 48 hours
  • Patient Isolation Breakdown: voltage 4000VAC 50Hz 60 seconds Leakage current <10μA
  • Frequency width Monitoring: mode 0.5 ~ 40Hz (+0.4dB,-3.0dB) Surgery mode 0.5 ~ 20Hz (+0.4dB, -3.0dB) not calibration significant
  • Patient Drive Current: <10μA
  • Enclosure Leakage Current: <0.1mA
  • Maximum T Wave Rejection Capability: 1.2mV
  • Heart Rate Alarm Response Time:< 7 seconds
  • Aspect Ratio: 0.24 ~ 0.6 sec/mV
  • Alarm Frequency Low alarm: 2-2.4kHz High alarm: 3-3.4kHz
  • Defibrillator Protected & ESIS Protected Tested with 5kV
  • Recovery Time Following Defibrillation: <5 seconds

RESP:

  • Measurement Method: Thoracic Impedance
  • Respiration Rate Range: 0 ~ 1001rpm
  • Accuracy: 2 rpm

Masimo SET SpO2

  • Measuring Range:
    • SpO2: 1?100 %
    • PR: 25?240 bpm
    • Perfusion: 0.02?20 %
  • SpO2 Accuracy (non-motion):
    • Adult Pediatric: 70?100 %: ±2 %, 0?69%: unspecified
    • Neonate: 70?100 %: ± 3 %,0?69 %: unspecified
  • SpO2 Accuracy (motion):
    • Adult Pediatric: 70?100 %: ±3 %, 0?69% : unspecified
    • Neonate: 70?100 %: ± 3 %, 0?69 % : unspecified
  • PR Accuracy (non-motion):
    • Adult Pediatric Neonate: 25?240 bpm: ±3 bpm
  • PR Accuracy (motion):
    • Adult Pediatric Neonate: 25?240 bpm: ±5 bpm
  • Low Perfusion Performance: >0.02 % Pulse Amplitude and % Transmission >5
    • SpO2: ±2 %
    • PR: ±3 bpm
  • Modes:
    • Averaging mode: 2,4,8,10,12,14 and 16 s
    • Sensitivity: Normal, APOD and Maximum

NIBP:

  • Method Automatic oscillometric
  • Parameters Systolic, diastolic, mean arterial pressure, pulse
  • Scale mmHg or kPa
  • Operating Modes Manual, Automatic, Continuous
  • Repeat Cycles 1 ~ 10, 15, 30, 60, 90, 120 minutes
  • Determination Systolic, Adult/pediatric 40 ~ 250mmHg (5.3 ~ 33.3kPa) Systolic, Neonate 20 ~ 160mmHg (2.7 ~ 21.3kPa) Diastolic, Adult/pediatric 10 ~ 180mmHg (1.3 ~ 24.0kPa) Diastolic, Neonate 10 ~ 140mmHg (1.3 ~ 18.7kPa)
  • Cuff Pressure Range Adult/pediatric 0 ~ 300mmHg (0 ~ 40.0kPa) Neonate 0 ~ 140mmHg (0 ~ 18.7kPa)
  • Initial Cuff Inflation Adult/pediatric 17010mmHg (22.7 1.3kPa) Neonate 10010mmHg (16.0 1.3kPa)
  • Deflation Pressure 30mmHg(4.0kPa) higher than the last systolic pressure
  • Cuff Inflation Rate No greater than 50mmHg/sec
  • Measurement Time Typical 25 seconds, Maximum 40 seconds, Typical Stat 20 seconds
  • Pressure Display Accuracy 3mmHg
  • BP Pulse Rate Accuracy 2% @ 40 ~240bpm
  • Cuff Neonate, infant, pediatric,standard adult

TEMP (Dual Channel)

  • Range 0 ~ 50C
  • Probe YSI 400 Skin surface or rectal /esophageal
  • Scale Celsius
  • Accuracy 0.1 C
  • Resolution 0.1 C

CO2 (Respironics) (mainstream or sidestream)

  • Type Side stream, mom-dispersive IR
  • CO2 Range 0-99mmHg
  • Scale mmHg/kPa
  • Accuracy +- 2mmHg (0-40mmHg) +- 5mmHg (41-76mmHg) +-10mmHg (77-99mmHg)
  • Calibration Automatic
  • Respiration Range 0-150rpm, +- 2rpm

TFT Color Display

  • Size 8 inches
  • Matrix 640 (H) x 480 (V) pixels
  • Recorder (Optional)
  • Type Built-in 2-channel thermal array recorder
  • Print mode Text or waveform
  • Waveforms Real time or alarm-triggered
  • Resolution 400dpi vertical, 800dpi horizontal
  • Annotations Time, date, vital sign readings